Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-37678606

RESUMO

OBJECTIVE: Ex vivo lung perfusion has emerged as a platform for organ preservation, evaluation, and restoration. Gene delivery using a clinically relevant adeno-associated vector during ex vivo lung perfusion may be useful in optimizing donor allografts while the graft is maintained physiologically active. We evaluated the feasibility of adeno-associated vector-mediated gene delivery during ex vivo lung perfusion in a rat transplant model. Additionally, we assessed off-target effects and explored different routes of delivery. METHODS: Rat heart-lung blocks were procured and underwent 1-hour ex vivo lung perfusion. Before ex vivo lung perfusion, 4e11 viral genome luciferase encoding adeno-associated vector 9 was administered via the left bronchus (Br group, n = 4), via the left pulmonary artery (PA group, n = 3), or directly into the circuit (Circuit group, n = 3). Donor lungs in the Control group (n = 3) underwent ex vivo lung perfusion without adeno-associated vector 9. Only the left lung was transplanted. Animals underwent bioluminescence imaging weekly before being killed at 2 weeks. Tissues were collected for luciferase activity measurement. RESULTS: All recipients tolerated the transplant well. At 2 weeks post-transplant, luciferase activity in the transplanted lung was significantly higher among animals in the Br group compared with the other 3 groups (Br: 1.1 × 106 RLU/g, PA: 8.3 × 104 RLU/g, Circuit: 3.8 × 103 RLU/g, Control: 2.5 × 103 RLU/g, P = .0003). No off-target transgene expression was observed. CONCLUSIONS: In this work, we demonstrate that a clinically relevant adeno-associated vector 9 vector mediates gene transduction during ex vivo lung perfusion in rat lung grafts when administered via the airway and potentially the pulmonary artery. Our preliminary results suggest a higher transduction efficiency when adeno-associated vector 9 was delivered via the airway, and delivery during ex vivo lung perfusion reduces off-target effects after graft implant.

2.
J Thorac Cardiovasc Surg ; 166(1): e38-e49, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38501313

RESUMO

OBJECTIVE: Adeno-associated virus is a clinically used gene therapy vector but has not been studied in lung transplantation. We sought to determine the efficacy of adeno-associated virus delivery during static cold storage via the airway versus the pulmonary artery before lung transplantation in a rodent model. METHODS: Lewis rat lung grafts were treated with a dose of 8e8 or 4e9 viral genome/µL recombinant adeno-associated virus subtype-9 vectors containing firefly luciferase genomes administered via the pulmonary artery or airway during cold storage. A control group did not receive adeno-associated virus. Recipient syngeneic rats then underwent single left lung transplantation. Animals underwent bioluminescence imaging on postoperative days 7, 14, 28, and 56. Explanted tissues were prepared as lysates to quantify luciferase activity. Immunohistochemistry was performed to evaluate cellular transgene expression patterns. RESULTS: Control animals with no luminescent signal produced a background radiance of 6.1e4 p/s/cm2/sr. In the airway delivery group, mean radiance was greater than the control at 4e9 viral genome/µL postoperative day 7 radiance 6.9e4 p/s/cm2/sr (P = .04). In the pulmonary artery delivery group, we observed greater in vivo luminescence in animals receiving 4e9 viral genome/µL compared with all other groups. However, analysis of tissue lysate revealed greater luminescence in the airway delivery group and suggested off-target expression in heart and liver tissue in the pulmonary artery delivery group. Immunohistochemistry demonstrated transgene staining in distal airway epithelium and alveoli but sparing of the vasculature in the airway delivery group. CONCLUSIONS: Adeno-associated virus mediates gene transduction during static cold storage in rat lung isografts when administered via the airway and pulmonary artery. Airway administration leads to robust transgene expression in respiratory epithelial cells, whereas pulmonary artery administration targets alternative cell types and increases extrapulmonary transgene expression.


Assuntos
Dependovirus , Transplante de Pulmão , Ratos , Animais , Dependovirus/genética , Roedores/genética , Ratos Endogâmicos Lew , Coração , Pulmão/metabolismo , Transplante de Pulmão/efeitos adversos , Vetores Genéticos
3.
Front Immunol ; 13: 931524, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35844566

RESUMO

Lung transplantation is the definitive therapy for patients living with end-stage lung disease. Despite significant progress made in the field, graft survival remains the lowest of all solid organ transplants. Additionally, the lung has among the lowest of organ utilization rates-among eligible donors, only 22% of lungs from multi-organ donors were transplanted in 2019. Novel strategies are needed to rehabilitate marginal organs and improve graft survival. Gene therapy is one promising strategy in optimizing donor allografts. Over-expression or inhibition of specific genes can be achieved to target various pathways of graft injury, including ischemic-reperfusion injuries, humoral or cellular rejection, and chronic lung allograft dysfunction. Experiments in animal models have historically utilized adenovirus-based vectors and the majority of literature in lung transplantation has focused on overexpression of IL-10. Although several strategies were shown to prevent rejection and prolong graft survival in preclinical models, none have led to clinical translation. The past decade has seen a renaissance in the field of gene therapy and two AAV-based in vivo gene therapies are now FDA-approved for clinical use. Concurrently, normothermic ex vivo machine perfusion technology has emerged as an alternative to traditional static cold storage. This preservation method keeps organs physiologically active during storage and thus potentially offers a platform for gene therapy. This review will explore the advantages and disadvantages of various gene therapy modalities, review various candidate genes implicated in various stages of allograft injury and summarize the recent efforts in optimizing donor lungs using gene therapy.


Assuntos
Transplante de Pulmão , Aloenxertos , Animais , Terapia Genética , Pulmão , Perfusão
4.
Front Med (Lausanne) ; 9: 804834, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35280912

RESUMO

Background: Subnormothermic machine perfusion (SNMP) of liver grafts is currently less clinically developed than normothermic and hypothermic approaches, but may have logistical advantages. At intermediate temperatures, the oxygen demand of the graft is low enough to be satisfied with an acellular perfusate, obviating the need for oxygen carrying molecules. This intermediate metabolic rate, however, is sufficient to support the production of bile, which is emerging as an important indicator of graft injury and viability. In this study, we hypothesized that the biliary compartment would be more sensitive than perfusate in detecting graft injury during SNMP. Methods: To test this hypothesis in a rat model, we performed liver transplants with DCD and control liver grafts after 1 h of acellular room temperature machine perfusion (acRTMP) or static cold storage (SCS). Point of care liver function tests were measured in biliary and perfusate samples after 1 h of machine perfusion. Following transplantation, rats were sacrificed at 24 h for assessment of post-transplant graft function and histology. Results: All point-of-care liver function tests were significantly more concentrated in the biliary compartment than the perfusate compartment during acRTMP. DCD liver grafts could be distinguished from control liver grafts by significantly higher markers of hepatocyte injury (AST, ALT) in the biliary compartment, but not in the perfusate compartment. Classical markers of cholangiocyte injury, such as gammy-glut amyl transferase (GGT), amylase (AML), and alkaline phosphatase were detectable in the biliary compartment, but not in the perfusate compartment. In comparison to SCS, graft preservation by acRTMP produced a significant survival benefit in DCD liver transplantation (75 vs. 0%, p < 0.0030). Conclusion: Together, these findings demonstrate that during acRTMP, the biliary compartment may be a more sensitive indicator of graft injury than the perfusate compartment. Moreover, acRTMP provides superior graft preservation to SCS in rat DCD liver transplantation.

5.
Am J Transplant ; 22(2): 552-564, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34379885

RESUMO

Ex vivo lung perfusion (EVLP) is a novel lung preservation strategy that facilitates the use of marginal allografts; however, it is more expensive than static cold storage (SCS). To understand how preservation method might affect postoperative costs, we compared outcomes and index hospitalization costs among matched EVLP and SCS preserved lung transplant (LTx) recipients at a single, high-volume institution. A total of 22 EVLP and 66 matched SCS LTx recipients were included; SCS grafts were further stratified as either standard-criteria (SCD) or extended-criteria donors (ECD). Median total preservation time was 857, 409, and 438 min for EVLP, SCD, and ECD lungs, respectively (p < .0001). EVLP patients had similar perioperative outcomes and posttransplant survival compared to SCS SCD and ECD recipients. Excluding device-specific costs, total direct variable costs were similar among EVLP, SCD, and ECD recipients (median $200,404, vs. $154,709 vs. $168,334, p =  .11). The median direct contribution margin was positive for EVLP recipients, and similar to that for SCD and ECD graft recipients (all p > .99). These findings demonstrate that the use of EVLP was profitable at an institutional level; however, further investigation is needed to better understand the financial implications of EVLP in facilitating donor pool expansion in an era of broader lung sharing.


Assuntos
Transplante de Pulmão , Preservação de Órgãos , Custos e Análise de Custo , Humanos , Pulmão , Transplante de Pulmão/métodos , Preservação de Órgãos/métodos , Perfusão/métodos , Doadores de Tecidos
8.
J Thorac Cardiovasc Surg ; 164(2): e59-e70, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-33640121

RESUMO

OBJECTIVE: Ex vivo lung perfusion has emerged as a novel technique to safely preserve lungs before transplantation. Recent studies have demonstrated an accumulation of inflammatory molecules in the perfusate during ex vivo lung perfusion. These proinflammatory molecules, including damage-associated molecular patterns and inflammatory cytokines, may contribute to acute and chronic allograft dysfunction. At present, ex vivo lung perfusion is performed clinically at normothermic temperature (37°C). The effect of lowering temperature to the subnormothermic range during ex vivo lung perfusion has not been reported. In this study, we hypothesized that lower ex vivo lung perfusion temperature will lead to a reduction in allograft inflammation and result in improved post-transplant graft function. METHODS: Lewis rat heart-lung blocs underwent 4 hours of ex vivo lung perfusion in 3 temperature groups: 37°C (MP37), 30°C (MP30), and 25°C (MP25). In the control group, lung grafts were preserved by static cold storage before transplantation. After ex vivo lung perfusion or static cold storage, the left lung was transplanted for 2 hours before the animal was killed. Sera and tissue were collected and analyzed. RESULTS: There were no differences in partial pressure of arterial oxygenation to fraction of inspired oxygen ratios during 4 hours of ex vivo lung perfusion between temperature groups. Tumor necrosis factor α significantly increased in the MP37 group during ex vivo lung perfusion, whereas this was not seen at lower temperatures. Extracellular DNA and high-mobility group box 1 perfusate concentrations increased significantly during ex vivo lung perfusion in all groups, but the rate of increase was diminished at lower temperature. Two hours post-transplant, there were no significant differences in partial pressure of arterial oxygenation to fraction of inspired oxygen ratios of the lung graft or serum damage-associated molecular pattern levels among groups. On histologic grading after transplantation, greater injury was observed in the MP30 and MP37 groups, but not MP25, when compared with static cold storage. CONCLUSIONS: Subnormothermic ex vivo lung perfusion at 25°C reduces the production of inflammatory mediators during ex vivo lung perfusion and is associated with reduced histologic graft injury after transplantation.


Assuntos
Transplante de Pulmão , Traumatismo por Reperfusão , Animais , Inflamação/etiologia , Inflamação/prevenção & controle , Pulmão , Transplante de Pulmão/efeitos adversos , Transplante de Pulmão/métodos , Preservação de Órgãos/métodos , Oxigênio , Perfusão/métodos , Ratos , Ratos Endogâmicos Lew , Traumatismo por Reperfusão/patologia
10.
J Clin Med ; 10(23)2021 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-34884207

RESUMO

The impact of HLA matching on graft survival has been well characterized in renal transplantation, with a higher degree of matching associated with superior graft survival. Additionally, living donor grafts are known to confer superior survival compared to those from deceased donors. The purpose of this study is to report our multi-decade institutional experience and outcomes for patients who received HLA-identical living donor grafts, which represent the most favorable scenario in kidney transplantation. We conducted a retrospective analysis of these graft recipients performed at a Duke University Medical Center between the years of 1965 and 2002. The recipients demonstrated excellent graft and patient survival outcomes, superior to a contemporary cohort, with median patient and graft survival of 24.2 and 30.9 years, respectively, among Duke recipients vs. 16.1 and 16.0 years in a cohort derived from national data. This study offers a broad perspective on the importance of HLA matching and graft type, and demonstrates a historical best-case-scenario in renal transplantation.

11.
Hepatol Commun ; 5(9): 1527-1542, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34510831

RESUMO

Normothermic machine perfusion (NMP) provides clinicians an opportunity to assess marginal livers before transplantation. However, objective criteria and point-of-care (POC) biomarkers to predict risk and guide decision making are lacking. In this investigation, we characterized trends in POC biomarkers during NMP and compared primate donation after circulatory death (DCD) livers with short and prolonged warm ischemic injury. Following asystole, livers were subjected to either 5 minutes (DCD-5min, n = 4) or 45 minutes (DCD-45min, n = 4) of warm ischemia time. Livers were flushed with heparinized UW solution, and preserved in cold storage before NMP. During flow-controlled NMP, circulating perfusate and tissue biopsies were collected at 0, 2, 4, 6, and 8 hours for analysis. DCD-45min livers had greater terminal portal vein pressure (8.5 vs. 13.3 mm Hg, P = 0.027) and terminal portal vein resistance (16.3 vs. 32.4 Wood units, P = 0.005). During perfusion, DCD-45min livers had equivalent terminal lactate clearance (93% vs. 96%, P = 0.344), greater terminal alanine aminotransferase (163 vs. 883 U/L, P = 0.002), and greater terminal perfusate gamma glutamyltransferase (GGT) (5.0 vs. 31.7 U/L, P = 0.002). DCD-45min livers had higher circulating levels of flavin mononucleotide (FMN) at hours 2 and 4 of perfusion (136 vs. 250 ng/mL, P = 0.029; and 158 vs. 293 ng/mL, P = 0.003; respectively). DCD-5min livers produced more bile and demonstrated progressive decline in bile lactate dehydrogenase, whereas DCD-45min livers did not. On blinded histologic evaluation, DCD-45min livers demonstrated greater injury and necrosis at late stages of perfusion, indicative of nonviability. Conclusion: Objective criteria are needed to define graft viability during NMP. Perfusate lactate clearance does not discriminate between viable and nonviable livers during NMP. Perfusate GGT and FMN may represent POC biomarkers predictive of liver injury during NMP.

12.
Transplant Direct ; 7(9): e742, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34386579

RESUMO

BACKGROUND: Livers from "nonideal" but acceptable donors are underutilized; however, organ procurement organization (OPO) metrics do not assess how OPO-specific practices contribute to these trends. In this analysis, we evaluated nonideal liver donor avoidance or risk aversion among OPOs and within US donation service areas (DSAs). METHODS: Adult donors in the United Network for Organ Sharing registry who donated ≥1 organ for transplantation between 2007 and 2019 were included. Nonideal donors were defined by any of the following: age > 70, hepatitis C seropositive, body mass index > 40, donation after circulatory death, or history of malignancy. OPO-specific performance was evaluated based on rates of nonideal donor pursuit and consent attainment. DSA performance (OPO + transplant centers) was evaluated based on rates of nonideal donor pursuit, consent attainment, liver recovery, and transplantation. Lower rates were considered to represent increased donor avoidance or increased risk aversion. RESULTS: Of 97 911 donors, 31 799 (32.5%) were nonideal. Unadjusted OPO-level rates of nonideal donor pursuit ranged from 88% to 100%. In a 5-tier system of overall risk aversion, tier 5 DSAs (least risk-averse) and tier 1 DSAs (most risk-averse) had the highest and lowest respective rates of non-ideal donor pursuit, consent attainment, liver recovery, and transplantation. On average, recovery rates were over 25% higher among tier 5 versus tier 1 DSAs. If tier 1 DSAs had achieved the same average liver recovery rate as tier 5 DSAs, approximately 2100 additional livers could have been recovered during the study period. CONCLUSION: Most OPOs aggressively pursue nonideal liver donors; however, recovery practices vary widely among DSAs. Fair OPO evaluations should consider early donation process stages to best disentangle OPO and center-level practices.

13.
J Heart Lung Transplant ; 40(11): 1463-1471, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34281776

RESUMO

BACKGROUND: Six hours was historically regarded as the limit of acceptable ischemic time for lung allografts. However, broader sharing of donor lungs often necessitates use of allografts with ischemic time >6 hours. We characterized the association between ischemic time ≥8 hours and outcomes after lung transplantation using a contemporary cohort from a high-volume institution. METHODS: Patients who underwent primary isolated bilateral lung transplantation between 1/2016 and 5/2020 were included. Patients bridged to transplant with extracorporeal membrane oxygenation or mechanical ventilation, and ex-vivo perfusion cases were excluded. Recipients were stratified by total allograft ischemic time <8 hours (standard) vs ≥8 hours (long). Perioperative outcomes and post-transplant survival were compared between groups. RESULTS: Of 358 patients, 95 (26.5%) received long ischemic time (≥8 hours) lungs. Long ischemic time recipients were more likely to be male and have donation after circulatory death donors than standard ischemic time recipients. On unadjusted analysis, long and standard ischemic time recipients had similar survival, and similar rates of grade 3 primary graft dysfunction at 72 hours, extracorporeal membrane oxygenation post-transplant, acute rejection within 30 days, reintubation, and post-transplant length of stay. After adjustment, long and standard ischemic time recipients had comparable risks of mortality or graft failure. CONCLUSIONS: In a modern cohort, use of lung allografts with "long" ischemic time ≥8 hours were associated with acceptable perioperative outcomes and post-transplant survival. Further investigation is required to better understand how broader use impacts post-lung transplant outcomes and the implications for smarter sharing under an evolving national allocation policy.


Assuntos
Oxigenação por Membrana Extracorpórea/métodos , Pneumopatias/cirurgia , Transplante de Pulmão , Disfunção Primária do Enxerto/prevenção & controle , Doadores de Tecidos , Adulto , Idoso , Aloenxertos , Feminino , Seguimentos , Sobrevivência de Enxerto , Humanos , Masculino , Pessoa de Meia-Idade , North Carolina/epidemiologia , Disfunção Primária do Enxerto/mortalidade , Estudos Retrospectivos , Taxa de Sobrevida/tendências , Fatores de Tempo
14.
Transplant Direct ; 7(3): e670, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34104709

RESUMO

Explantation of native viscera in multivisceral transplant candidates, particularly in those with extensive portomesenteric thrombosis (PMT), carries considerable morbidity due to extensive vascularized adhesions. Preemptive visceral angioembolization has been previously described as a technique to minimize excessive blood loss during mobilization of the native viscera but is not well described specifically in patients with extensive PMT. METHODS: In a series of 5 patients who underwent mutivisceral transplant for PMT from June 2015 to November 2018, we performed preoperative superior mesenteric, splenic, and hepatic artery embolization to reduce blood loss during explanation and evaluated the blood loss and blood product utilization, as well as 30-day rates of infectious complications. RESULTS: Following preemptive embolization, median total blood loss was 6000 mL (range 800-7000 mL). The median transfusion requirements were as follows: 16 units packed red blood cells (range 2-47), 14 units fresh frozen plasma (range 0-29), 2 units cryoprecipitate (range 1-14), 4 units platelets (range 2-10), and 500 mL cell saver autotransfusion (range 0-1817). In the first 30 postoperative days, 2 out of 5 patients developed positive blood cultures and 3 out of 5 developed complex intra-abdominal infections. Two patients developed severe graft pancreatitis resulting in mycotic aneurysm of the aortic conduit; bleeding from the aneurysm led to 1 patient mortality. CONCLUSIONS: Preoperative embolization is an effective modality to mitigate exsanguinating blood loss during multivisceral transplant in patients with portomesenteric thrombosis; however, it is unclear if the resultant native organ ischemia during explant carries clinically relevant consequences.

15.
Hepatobiliary Surg Nutr ; 10(3): 315-324, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34159159

RESUMO

BACKGROUND: Selection of the optimal treatment modality for primary liver cancers remains complex, balancing patient condition, liver function, and extent of disease. In individuals with preserved liver function, liver resection remains the primary approach for treatment with curative intent but may be associated with significant mortality. The purpose of this study was to establish a simple scoring system based on Model for End-stage Liver Disease (MELD) and extent of resection to guide risk assessment for liver resections. METHODS: The 2005-2015 NSQIP database was queried for patients undergoing liver resection for primary liver malignancy. We first developed a model that incorporated the extent of resection (1 point for major hepatectomy) and a MELD-Na score category of low (MELD-Na =6, 1 point), medium (MELD-Na =7-10, 2 points) or high (MELD-Na >10, 3 points) with a score range of 1-4, called the Hepatic Resection Risk Score (HeRS). We tested the predictive value of this model on the dataset using logistic regression. We next developed an optimal multivariable model using backwards sequential selection of variables under logistic regression. We performed K-fold cross validation on both models. Receiver operating characteristics were plotted and the optimal sensitivity and specificity for each model were calculated to obtain positive and negative predictive values. RESULTS: A total of 4,510 patients were included. HeRS was associated with increased odds of 30-day mortality [HeRS =2: OR =3.23 (1.16-8.99), P=0.025; HeRS =3: OR =6.54 (2.39-17.90), P<0.001; HeRS =4: OR =13.69 (4.90-38.22), P<0.001]. The AUC for this model was 0.66. The AUC for the optimal multivariable model was higher at 0.76. Under K-fold cross validation, the positive predictive value (PPV) and negative predictive value (NPV) of these two models were similar at PPV =6.4% and NPV =97.7% for the HeRS only model and PPV =8.4% and NPV =98.1% for the optimal multivariable model. CONCLUSIONS: The HeRS offers a simple heuristic for estimating 30-day mortality after resection of primary liver malignancy. More complicated models offer better performance but at the expense of being more difficult to integrate into clinical practice.

16.
Liver Transpl ; 27(8): 1106-1115, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33733560

RESUMO

Historically in the United States, kidneys for simultaneous liver-kidney transplantation (SLKT) candidates were allocated with livers, prioritizing SLKT recipients over much of the kidney waiting list. A 2017 change in policy delineated renal function criteria for SLKT and implemented a safety net for kidney-after-liver transplantation. We compared the use and outcomes of SLKT and kidney-after-liver transplant with the 2017 policy. United Network for Organ Sharing Standard Transplant Analysis and Research files were used to identify adults who received liver transplantations (LT) from August 10, 2007 to August 10, 2012; from August 11, 2012 to August 10, 2017; and from August 11, 2017 to June 12, 2019. LT recipients with end-stage renal disease (ESRD) were defined by dialysis requirement or estimated glomerular filtration rate <25. We evaluated outcomes and center-level, regional, and national practice before and after the policy change. Nonparametric cumulative incidence of kidney-after-liver listing and transplant were modeled by era. A total of 6332 patients received SLKTs during the study period; fewer patients with glomerular filtration rate (GFR) ≥50 mL/min underwent SLKT over time (5.8%, 4.8%, 3.0%; P = 0.01 ). There was also less variability in GFR at transplant after policy implementation on center and regional levels. We then evaluated LT-alone (LTA) recipients with ESRD (n = 5408 from 2012-2017; n = 2321 after the policy). Listing for a kidney within a year of LT increased from 2.9% before the policy change to 8.8% after the policy change, and the rate of kidney transplantation within 1 year increased from 0.7% to 4% (P < 0.001). After the policy change, there was no difference in patient survival rates between SLKT and LTA among patients with ESRD. Implementation of the 2017 SLKT policy change resulted in reduced variability in SLKT recipient kidney function and increased access to deceased donor kidney transplantation for LTA recipients with kidney disease without negatively affecting outcomes.


Assuntos
Transplante de Fígado , Adulto , Humanos , Rim/fisiologia , Rim/cirurgia , Fígado , Políticas , Diálise Renal , Estudos Retrospectivos , Estados Unidos/epidemiologia
17.
World J Surg ; 45(5): 1504-1513, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33486584

RESUMO

BACKGROUND: "Textbook outcome" (TO) is a novel composite quality measure that encompasses multiple postoperative endpoints, representing the ideal "textbook" hospitalization for complex surgical procedures. We defined TO for kidney transplantation using a cohort from a high-volume institution. METHODS: Adult patients who underwent isolated kidney transplantation at our institution between 2016 and 2019 were included. TO was defined by clinician consensus at our institution to include freedom from intraoperative complication, postoperative reintervention, 30-day intensive care unit or hospital readmission, length of stay > 75th percentile of kidney transplant patients, 90-day mortality, 30-day acute rejection, delayed graft function, and discharge with a Foley catheter. Recipient, operative, financial characteristics, and post-transplant patient, graft, and rejection-free survival were compared between patients who achieved and failed to achieve TO. RESULTS: A total of 557 kidney transplant patients were included. Of those, 245 (44%) achieved TO. The most common reasons for TO failure were delayed graft function (N = 157, 50%) and hospital readmission within 30 days (N = 155, 50%); the least common was mortality within 90 days (N = 6, 2%). Patient, graft, and rejection-free survival were significantly improved among patients who achieved TO. On average, patients who achieved TO incurred approximately $50,000 less in total inpatient charges compared to those who failed TO. CONCLUSIONS: TO in kidney transplantation was associated with favorable post-transplant outcomes and significant cost-savings. TO may offer transplant centers a detailed performance breakdown to identify aspects of perioperative care in need of process improvement.


Assuntos
Transplante de Rim , Adulto , Rejeição de Enxerto , Sobrevivência de Enxerto , Humanos , Readmissão do Paciente , Assistência Perioperatória , Indicadores de Qualidade em Assistência à Saúde , Estudos Retrospectivos
18.
Adv Healthc Mater ; 10(5): e2000321, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33034955

RESUMO

Light-controlled sequential photolysis from a single nanoparticle is a challenge for controlled release. A wavelength-selective sequential photolysis from single gold nanoparticles is reported for the first time. In particular, it is also demonstrated that such nanoparticle can be used to sequentially release two payloads in living cells. In principle, this system can be extended to sequential release of multiple different types of payloads by rational design of diverse photocleavable linkers. It is expected that this work can provide a new tool for better orderly controlling cellular events that request high spatiotemporal manners.


Assuntos
Nanopartículas Metálicas , Nanopartículas , Ouro , Fotólise
20.
Liver Transpl ; 27(3): 425-433, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33188659

RESUMO

Liver grafts from pediatric donors represent a small fraction of grafts transplanted into adult recipients, and their use in adults requires special consideration of donor size to prevent perioperative complications. In the past, graft weight or volume ratios have been adopted from the living donor liver transplant literature to guide clinicians; however, these metrics are not regularly available to surgeons accepting deceased donor organs. In this study, we evaluated all pediatric-to-adult liver transplants in the United Network for Organ Sharing Standard Transplant Analysis and Research database from 1987 to 2019, stratified by donor age and donor-recipient height mismatch ratio (HMR; defined as donor height/recipient height). On multivariable regression controlling for cold ischemia time, age, and transplantation era, the use of donors from ages 0 to 4 and 5 to 9 had increased risk of graft failure (hazard ratio [HR], 1.81 [P < 0.01] and HR, 1.16 [P < 0.01], respectively) compared with donors aged 15 to 17. On Kaplan-Meier survival analysis, a HMR < 0.8 was associated with inferior graft survival (mean, 11.8 versus 14.6 years; log-rank P < 0.001) and inferior patient survival (mean, 13.5 versus 14.9 years; log-rank P < 0.01) when compared with pairs with similar height (HMR, 0.95-1.05; ie, donors within 5% of recipient height). This study demonstrates that both young donor age and low HMR confer additional risk in adult recipients of pediatric liver grafts.


Assuntos
Transplante de Fígado , Obtenção de Tecidos e Órgãos , Adolescente , Adulto , Criança , Sobrevivência de Enxerto , Humanos , Estimativa de Kaplan-Meier , Transplante de Fígado/efeitos adversos , Doadores Vivos , Estudos Retrospectivos , Doadores de Tecidos , Transplantados , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...